Flange Integrity Assessment with Gasket Modeling
Structural verification of RTJ and RF flanged joints at a Metering Station under loads, with detailed modeling of the spiral-wound graphite gasket's non-linear mechanical behavior.
- Көлем
- FEA in Abaqus with gasket contact modeling under load
- Нәтиже
- Optimal flange type selected for the upgrade